SAFETY INFORMATION OVERVIEW OF POTENTIAL HAZARDS READ THIS SAFETY INFORMATION Garage doors are large, heavy objects that move with the help of springs under high tension and electric motors. Since moving objects, springs under tension, and electric motors can cause injuries, your safety and the safety of others depend on the owner or user of this system to read, understand and implement the information in this manual. If you have questions or do NOT ® understand the information presented, conta

Inhaltszusammenfassung zur Seite Nr. 3

TABLE OF CONTENTS OPENER FEATURES ® SECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PAGE INTELLICODE Rolling Code Security System. An electronic rolling code system that enhances the security of SAFETY INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 the door opener by continuously changing the access code each time the remote control is used. The door opener OPENER FEATURES. . . . . . . . . . . . . . . . . . . . . . . . .

Inhaltszusammenfassung zur Seite Nr. 4

FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM PRE-INSTALLATION CHECK LIST Things to consider if you are planning to "Do-it-yourself." This opener is designed for use with SECTIONAL doors only. In many cases you will be replacing an existing door opener with a new one, however, if this will be the first opener installed there are some pre-installation issues which need to be addressed. They are as follows: The Genie Company recommends that you read and fully understand all information and in

Inhaltszusammenfassung zur Seite Nr. 5

TYPICAL SECTIONAL DOOR INSTALLATION FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM Pg. 19 Pg. 13 5 1 Pg. 12-13 2 TYPICAL SUPPORT ADDED BRACKET HEADER BRACKET (NOT PROVIDED) MOUNTING BOARD BRACES POWER CORD (APPROX. 45 IN.) TO 120V GROUNDED OUTLET EXTENSION SPRING OR TORSION SPRING Pg. 14 4 NOTE: This opener is designed for Pg. 17-18 use with SECTIONAL doors only. Pg. 17-18 6 3 3 Pg. 11 ® SAFE-T-BEAM MAX. 6" MIN. 5" 7 Pg. 12 SECTIONAL DOOR WARNING To reduce the risk of injury to persons or damag

Inhaltszusammenfassung zur Seite Nr. 6

RECOMMENDED TOOLS FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM Pencil 3/16" Drill Bit Carpenter’s level Drill Wire strippers Adjustable wrench Ratchet Tape measure Safety Glasses Step ladder Hammer 1/4", 7/16", 3/8" and Phillips screwdriver 1/2" Sockets PARTS IDENTIFICATION - Not Shown Full Size . ARRANGING BOX CONTENTS FOR ASSEMBLY ORGANISATION DU CONTENU DE LA BOÎTE POUR LE MONTAGE DISPOS CIÓN DEL CONTEN DO DE LA BOLSA PARA EL MONTA E Remove i te nal box s nl ve l s bo t s i t rn s Qu

Inhaltszusammenfassung zur Seite Nr. 7

Shown Full size ( FASTENERS - See Parts List below for full description.) BAG NO. DESCRIPTION QUANTITY 0 RAIL SECTION CLAMP 2 RAIL CLAMP BOLT – 5/16 -18 x 5/8'' 8 HEX FLANGE NUT – 5/16 -18 8 1 BOLT – 5/16 -18 x 1/2'' 3 Rail Clamp Bolt - 5/16 -18 x 5/8" 2 CLEVIS PIN, LONG – 5/16" x 3" 1 COTTER PIN 1 HEADER BRACKET 1 LAG SCREW – 5/16'' x 2'' 2 3 HEX BOLT – 5/16 -18 x 3/4'' 5 #10-16 x 1-1/4" Phillips Hex Screw HEX FLANGE NUT – 5/16 -18 5 LAG SCREW – 5/16'' x 2'' 2 4 SELF DRILLING SCREW – 1/4 -20 x

Inhaltszusammenfassung zur Seite Nr. 8

FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM 1-PIECE RAIL HARDWARE ASSEMBLED VIEW Power Cord Carriage Assembly Rail with chain Chain Connector Power Head CHAIN Release Knob Tensioner Chain Clevis Pin, Long BELT Header & Cotter Pin Bracket 3-PIECE RAIL HARDWARE ASSEMBLED VIEW Power Cord Carriage Assembly Rail with chain Rail Clamps Power Head Chain Connector Rail Clamp Bolts Release CHAIN Knob Rail with belt End Rail Rail Clamp Nuts Center Rail Tensioner Chain End Rail Clevis Pin, Long

Inhaltszusammenfassung zur Seite Nr. 9

IMPORTANT INSTALLATION INSTRUCTIONS WARNING: To reduce the risk of severe injury or death: 1. READ AND FOLLOW ALL SAFETY, INSTALLATION AND 5. Do NOT connect the opener to source of power until OPERATION INSTRUCTIONS. (If you have questions or do instructed to do so. not understand an instruction, call the Overhead 6. Locate the wall console: Door Corporation.) • Within sight of the garage door, 2. Install only on a properly balanced sectional or one piece • At minimum height of 5 feet so

Inhaltszusammenfassung zur Seite Nr. 10

Belt Rail Assembly for CHAIN DRIVE OPENER CHAIN DRIVE RAILS NOTE: For split rail clamps, nuts, and bolts locate Bag 0 from Box 1. Chain Rail Center Rail A 3. Remove the two rail sections that are not connected to the chain and place them on floor (Fig. 1-2, A). End Rail 4. Carefully remove the third rail section with chain and plastic sleeve. Place rail section on floor and extend chain straight out Wire Tie(s) B (Fig. 1-2, B). Chain and rail should extend approximately 7 feet. 5. Remove wire

Inhaltszusammenfassung zur Seite Nr. 11

POWER HEAD & RAIL ASSEMBLY Use 5/16"-18 x 1/2" Assembly for CHAIN DRIVE OPENER Bolts NOTE: Handle carefully! Drive chain can slide out of rail. NOTE: For power head and rail assembly locate Bag 1 from Box 1. NOTE: Copy serial number from power head frame and record it on warranty page. FIG. 1-5 Rail - Power head assembly. 1. Attach rail assembly to power head by aligning the sprocket onto the motor shaft. Use (3) Chain Pulley Bracket (at wall end of rail) bolts, 5/16 -18 x 1/2" (Fig. 1-5). Use

Inhaltszusammenfassung zur Seite Nr. 12

final height mark door at highest point final height mark 2 1/2" door at highest point OPENER INSTALLATION FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM 2 b) - extend HEADER AND DOOR vertical line MOUNTING BRACKETS: 2-1/2" WARNING Header bracket must be fastened to garage d) - final c) - door at framing. Do NOT fasten to drywall, particle height mark board, plaster or other such materials. highest point 1. Finding header bracket mounting location. • Close garage door. – Use a pencil and l

Inhaltszusammenfassung zur Seite Nr. 13

NO HEADER BRACKET MOUNTING THE OPENER: 1. Getting started. • Position assembled rail on wall next to header bracket (Fig. 2-4). – Place material on floor under power head to protect from scratching. (A box, stool, or VIEW similar device may be needed to clear a FROM ABOVE (not to scale) torsion spring.) NOTE: For header bracket pins locate Bag 2 from Box 1. 2. Mounting the assembly. YES / SÍ / OUI • Attach rail to header bracket using clevis pin and cotter pin (Fig. 2-5). FIG. 2-4 Positio

Inhaltszusammenfassung zur Seite Nr. 14

DOOR BRACKET: CAUTION Doors made of masonite, lightweight wood, centerline fiberglass, and sheet metal must be properly braced before mounting door opener. Contact door manufacturer or distributor for a bracing kit. centerline The Genie Company is not responsible for even with or damage caused due to improperly braced door. above top roller NOTE: For door bracket and bolts locate Bag 4 FIG. 2-7 Mounting door Bracket. from Box 2. 1. Finding door bracket mounting location. • Door bracket is mo

Inhaltszusammenfassung zur Seite Nr. 15

WALL CONSOLE INSTALLATION FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM 3 Wire from WARNING power head Verify there is NO power to the opener before to Wall Console installing Wall Console wires and Wall Console. CAUTION Staples which are too tight can cut or pinch wires. Cut or pinched wires can cause the Wall Console to stop working. When using the insulated staples, make sure you fasten them only as tightly as needed to hold the wire snugly. Wall Console WARNING "Entrapment" Use of any

Inhaltszusammenfassung zur Seite Nr. 16

Child can be pinned under automatic garage door. Death or serious injury can result. •Never let child walk or run under moving do.or. Never let child use door opener controls. • Always keep moving door in sight. • •If person is pinned, push control button or use emergency release. Test door opener monthly: • Refer o your owner s manual P ace 1/ - nch object (or 2x4 laid f at) on floor If door a ls o reverse on con act adjust opener If opener s i l a ls o reverse door repair or replace open

Inhaltszusammenfassung zur Seite Nr. 17

® AFE-T-BEAM SYSTEM INSTALLATION FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM 4 WARNING There should be no electrical power to the opener ® while installing Safe-T-Beam wires. If you have plugged in the power cord—UNPLUG IT NOW! N OTE: The opener will not close the door ® automatically unless the Safe-T-Beam System is installed. mark NOTE: For Safe-T-Beam®, screws, wire, and insulated staples locate items and Bag 8 from Box 3. FIG. 4-1 Mark door frame. 1. Mounting brackets. • Mark both si

Inhaltszusammenfassung zur Seite Nr. 18

3b. Wiring (pre-wired). ® • Route wire from wall to Safe-T-Beam sensors Wall Wall (Fig. 4-5b). • Splice pre-wiring to shortened sensor wire, Source Sensor match wire pairs dash-to-dash (striped-to- striped) and plain-to-plain (white-to-white). - Trim sensor wire to approximately one foot (1 ft) from sensor. - Split and strip ends of sensor wires and Ceiling 6 5 4 3 2 1 or 6 5 4 3 2 1 pre-wired wires (Fig. 4-7). - Splice wires together with (provided) Power Dashed Lin

Inhaltszusammenfassung zur Seite Nr. 19

ONNECTING TO POWER FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM 5 WARNING • To reduce the risk of electrical shock, this equipment FIG. 5-1 Connect to power. has a grounded type plug that includes a third (grounding) pin. This plug will only fit a grounded type outlet. If you do not have a grounded outlet, contact Motor Cover Screws a qualified licensed electrician to install one. DO NOT alter the plug in any way. The door opener must be properly grounded in order to prevent personal injur

Inhaltszusammenfassung zur Seite Nr. 20

Move in this direction Move in this direction OOR LIMITS FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM 6 WARNING Limit Controls location on power head. • Severe injury or death can result if the door closing force is set too high. NOTE: Set Close Travel Limit • Never increase the door closing force above the before setting Open Travel minimum required to move the door. Limit for unit to operate • Never adjust force to compensate for a sticking normally. or binding door. Unless limits ar

Bedienungsanleitung Genie 2022 (2024)

FAQs

Why does my Genie garage door opener not work? ›

Opener does NOT operate when the wall console is pressed

Plug a lamp into the same outlet, if the lamp works the power source is ok, if the lamp does not work, check the fuse or breaker. Check for reversed, broken, or cut wires. Staples can cut insulation and short out the wires.

How do you reset a Genie garage door opener after a power outage? ›

Hard Reset
  1. PRESS and HOLD the down arrow button taking the door down to the ground. ...
  2. PRESS and HOLD the down arrow set button, count 10 seconds, then RELEASE the button.
  3. PRESS and HOLD the up arrow button taking the door up keeping it about 4 inches from the motor.

Why is my garage door opener getting power but not working? ›

Check Garage Door Opener Mechanism

If the garage door opener is receiving power but still not operating properly, it could have a mechanical failure. If the door won't open but the engine sounds like it's running, the main gear drive may have broken and need replacement.

Why is my Genie garage door opener remote not working after battery change? ›

After placing fresh batteries in your remote, if the door still won't respond, then the signal between the remote and opener transmitter may be disrupted. Two common causes for a signal interruption is if your remote is out of range or the opener receiving antennae is damaged.

Why wont my garage door open with code? ›

Dead batteries

This could be the problem if you haven't changed your garage door keypad batteries in a while. Change your batteries and see if the keypad starts working again. Older battery compartments on garage door keypads use 12-volt batteries, while newer models use 9-volt batteries.

How do you reset the open and close limit on a garage door? ›

Garage Door Closes & Opens Back Up

Using a flathead screwdriver, turn the down limit switch adjustment screw on the side of the garage door opener clockwise by one turn. Open and close the garage door, adjusting the down limit switch one turn at a time until the door operates normally.

What is the limit button on garage door? ›

This garage door limit switch is a device that electrically controls or limits the extent to which a garage door can travel while opening or closing. If the limit switch is set incorrectly or malfunctions, the door may refuse to close fully or reverses itself while the homeowner attempts to shut it.

Will unplugging a garage door opener reset it? ›

Will unplugging a garage door opener reset it? Yes, unplugging a garage door opener will reset it. Unplugging the opener erases the programmed settings. You will have to reprogram it again once you plug it in.

What does a solid red light mean on a Genie garage door opener? ›

For example, if both LEDs are a steady red, this means that the limits are not properly set and need to be reprogrammed.

Why is the purple light flashing on my Genie garage door opener? ›

When it switches to purple and blinks press and hold the 2 triangular button down at the same time until the lights turn blue and let go. This should clear all remote systems to this opener. ) If you are in need of an Intellicode transmitter (GIT-1), you can find them on our Web site in the Genie section.

What does a blinking red light mean on a Genie garage door opener? ›

Helpful Advice For Troubleshooting Genie® Garage Door Openers: Flashing Red Lights. Are you having trouble opening or closing your Genie® garage door? Are the LED lights on your opener flashing red? If they are, your system has likely detected an error like a system blockage, faulty component, or programming error.

Top Articles
Latest Posts
Article information

Author: Corie Satterfield

Last Updated:

Views: 6083

Rating: 4.1 / 5 (62 voted)

Reviews: 93% of readers found this page helpful

Author information

Name: Corie Satterfield

Birthday: 1992-08-19

Address: 850 Benjamin Bridge, Dickinsonchester, CO 68572-0542

Phone: +26813599986666

Job: Sales Manager

Hobby: Table tennis, Soapmaking, Flower arranging, amateur radio, Rock climbing, scrapbook, Horseback riding

Introduction: My name is Corie Satterfield, I am a fancy, perfect, spotless, quaint, fantastic, funny, lucky person who loves writing and wants to share my knowledge and understanding with you.